Boiler diagrams, spare parts and user manuals for Halstead WICKES LW 50CI (EXPLODED VIEW) 24 hour delivery on genuine manufacturer boiler spares 30 day money back guarantee. OBSOLETE NAMEPLATE WICKES LW50CI Halstead part n o. 750741: 14: OBSOLETE NAMEPLATE WICKES LW60CI Halstead part n o. 750753: 14: OBSOLETE NAMEPLATE WICKES LW40CI. Halstead Htg Spares. Halstead boiler spares can be located quickly using the Boiler Spare Parts Finder tool from PlumbNation, in a few simple steps we will let you know whether we have the Halstead spares you need. PlumbNation is part of Travis Perkins plc, a FTSE 100 company and a market leading supplier of home improvement and building products.

Halstead Wickes Combi 102 Manual

Halstead Wickes Combi 102 Manual

Central heating was working fine.I woz surprised because. Well because as you can see the pressure was Zero.

Well it it not as bad it looks. I can explain. It was confirmed that the pressure is fine but the pressure gauge is stuck on zero. Okey good looking.

Combi

So why the hack hot water is not coming. Not even the demand light is coming on.

Well you got it. If there is not even demand light is coming. Dont look no further.! Got the boiler working within 3 hours on a Sunday.thanks Hawk heating to keep the Wicks boikler parts. I never thought I will find the part.ANyway Job done the same day.

Perhaps I should have a takeaway for Dinner.!

Hi all-what a brill forum! Finally moved from lurking to posting!! I recently bought my first property-3 bed terrace-v exciting. I've been doing a lot of the work on it myself Sarah Beeny style but had to call a heating engineer out last week to look at my boiler-a Wickes 102 combi (Halstead) because it stopped making hot water but heating was working.

The engineer had a really good look at it and said it was probably the diverter valve/diaphragm. He changed that and it did make hot water for a few minutes but then stopped again. Now heating and hot water not working.:( He is recommending I replace boiler as he says it is probably PCB which is expensive esp for Halstead.

I just wanted to check with you guys as I've lurked some fab advice from here before. I don't think he is trying to rip me off but am a bit annoyed that I will have to pay for the first part and fitting and now this. Thanks in advance!! Repairs to Halsteads are v expensive unfortunately, but even replacing a pcb (if it is really necessary) would still be a lot cheaper than a new boiler Low voltage wiring harness is very prone to having wires break in it. I would get him to test this out first. If the hot water only worked for a short while I would say he hasn't fixed anything and hasn't a clue what is actually wrong with it, hence trying to sell you a new boiler.

If it truly was the diaphragm, then this would have been a permanent repair. Worth double checking from my experience:- My Son's boiler packed up, his house maintenance insurance sent a Techy, he said it was the pcb and expensive might be better to consider new boiler date during the last very cold spell, Son could not wait ( two babies in house) for the part approval and bought pcb, he called me after this did not work, went over, had a look at old pcb-glass fuse was blown-checked around and found only the fan could do this-checked fan and found tight-Son bought new fan-installed all good-insurance part never arrived! Re the last post, replacing the fan should not be considered as a DIY job as it involves desturbing the integrity of the combustion chamber.

5 explanations, 6 meanings to Statue lyrics by Lil Eddie: When a day is said and done, / In the middle of the night and you're fast asleep. Statue lil eddie ukulele. Statue - Lil Eddie (LYRICS). Statue - Lil Eddie (LYRICS) Statue - Lil Eddie Statue Lil Eddie Lyrics Music Song Love Song Ella Banana. Animator Ella. Lyrics to 'Statue' by Lil Eddie: When a day is said and done In the middle of the night and your fast asleep, my love.

Your repairer obviously has no ability to diagnose and repair boiler faults. It is very likely to be a PCB fault though. These are expensive at about £150 but always cheaper than a new boiler. The pcb is very prone to bad solder joints and I usually manage to repair them by resoldering. Normally I only fit new parts but on that model the price is so high for a poorly made component so the customer saves.